Logo Kérwá
 

LBDNet inter-laboratory comparison at high doses of ionizing radiation using the dicentric plus caffeine assay

dc.creatorRomero Aguilera, Ivonne
dc.creatorMandina Cardoso, Tania
dc.creatorCabitto, Mariana
dc.creatorDeminge, Mayra
dc.creatorFernández Rearte, Julieta
dc.creatorVaquero, Hernán
dc.creatorFarias de Lima Guimarães, Fabiana
dc.creatorEsposito Mendes, Mariana
dc.creatorMelo da Silva, Laís
dc.creatorLafuente Álvarez, Erika Flavia
dc.creatorRada Tarifa, Ana María Lourdes
dc.creatorVerdejo, Valentina
dc.creatorRadl, Analia
dc.creatorSaavedra Cuevas, Nicolás
dc.creatorSantibañez Villobos, Mauricio Andrés
dc.creatorBrenes Obando, Nelson
dc.creatorChaves Campos, Fabio Andrés
dc.creatorOrtíz Morales, Fernando
dc.creatorValle Bourrouet, Luisa María
dc.creatorGonzález Mesa, Jorge Ernesto
dc.creatorBastidas Martínez, Ángela María
dc.creatorMuñoz Velástegui, Gabriela Elizabeth
dc.creatorArceo Maldonado, Carolina
dc.creatorGuerrero Carbajal, Yolanda Citlali
dc.creatorAguilar Coronel, Sara Elena
dc.creatorMonjagata de Ortiz, Norma
dc.creatorEspinoza Zevallos, Marco
dc.creatorMartínez López, Wilner
dc.creatorMechoso, Burix
dc.creatordi Tomaso di Prato, María Vittoria
dc.creatorFalcón de Vargas, Aida Beatriz
dc.creatorGarcía Lima, Omar
dc.date.accessioned2025-10-13T15:27:08Z
dc.date.issued2025-05-05
dc.description.abstractPurpose: To assess the performance of the LBDNet laboratories in estimating dose over 5Gy of ionizing radiation using the dicentric chromosome plus caffeine assay. Materials and methods: Dose-response curve fitting: Peripheral blood was irradiated in vitro between 5 and 25Gy. Then, the DC plus caffeine assay was carried out. Thirteen laboratories received and analyzed metaphase images. The linear dose-response curve was fitted for each laboratory. Dose estimation was performed analyzing coded metaphase images from three different irradiated samples (7.5, 15, 20Gy) and using the fitted curve from every laboratory. Results: The dose estimation accuracy was within the expected dose ranges. The 76.9%, 84.6% and 69.2% of the estimated doses fell into the ± 20% of the true radiation dose. The 92.3%, 92.3%, and 61.5% of the 95% of the confidence interval of the estimated doses included the true radiation dose. The trueness was 0.9%, 4.4% and 9.6%. The Coefficients of Variation of the estimated doses were 14.5%, 16.1% and 17.8%. Results from only one laboratory were deemed questionable for dose estimation, based on the Z-score derived from robust methods. Conclusion: The intercomparison study yielded satisfactory results; however, dose estimation accuracy tended to decrease, and variability between laboratory results increased as the dose level rose.
dc.description.procedenceUCR::Vicerrectoría de Investigación::Unidades de Investigación::Ciencias de la Salud::Instituto de Investigaciones en Salud (INISA)
dc.description.sponsorshipOrganismo Internacional de Energía Atómica/[RLA 9076]/OIEA/Austria
dc.description.sponsorshipSistema Regional de Cooperación para la Vigilancia de la Seguridad Operacional/[ME-RLA-9091]/SRVSOP/Perú
dc.description.sponsorshipAgencia Nacional de Investigación y Desarrollo/[21220341]/ANID/Chile
dc.description.sponsorshipUniversidad de La Frontera/[]/UFRO/Chile
dc.description.sponsorshipFundação de Amparo à Ciência e Tecnologia de Pernambuco/[]/FACEPE/Brasil
dc.identifier.doihttps://doi.org/10.1080/09553002.2025.2494554
dc.identifier.issn0955-3002
dc.identifier.issn1362-3095
dc.identifier.urihttps://hdl.handle.net/10669/102960
dc.language.isoeng
dc.relation.ispartofseries0
dc.rightsacceso abierto
dc.sourceInternational Journal of Radiation Biology, 101(6), 636-651
dc.subjectinterlaboratoy comparison
dc.subjecthigh radiation doses
dc.subjectdicentric chromosome plus caffeine assay
dc.subjectbiodosimetry
dc.titleLBDNet inter-laboratory comparison at high doses of ionizing radiation using the dicentric plus caffeine assay
dc.typeartículo original

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
FCHC- LBDNet inter-laboratory comparison at high doses of ionizing radiation using the dicentric plus caffeine assay.pdf
Size:
8.24 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
3.5 KB
Format:
Item-specific license agreed upon to submission
Description: