Evaluación de la Seguridad Radiológica del CICANUM: Laboratorio de Metrología de Radiaciones Ionizantes y Almacén de Residuos Radiactivos
dc.creator | Noguera Vega, Gerardo | |
dc.creator | Mora Rodríguez, Patricia | |
dc.date.accessioned | 2023-07-18T16:35:17Z | |
dc.date.available | 2023-07-18T16:35:17Z | |
dc.date.issued | 2018 | |
dc.description.abstract | El Centro de Investigación en Ciencias Atómicas, Nucleares y Moleculares (CICANUM) posee laboratorios que constituyen un riesgo radiológico latente, tales como, el Laboratorio de Metrología de Radiaciones Ionizantes (LMRI) en el cual se encuentran fuentes de Cs-137, Am-241 y Sr-90 y, un equipo de rayos X con blancos de tungsteno de 225 kV y molibdeno de 50 kV; otro laboratorio es el Almacén de Residuos Radiactivos que contiene residuos radiactivos de diferentes semiperíodos. Por tal razón, organismos internacionales recomiendan realizar una evaluación integral de los laboratorios en aras de la protección del personal expuesto. Así, el objetivo de este estudio fue evaluar el CICANUM para evidenciar fortalezas y debilidades de las barreras y mitigadores que se tienen implementados y así reducir el riesgo de una exposición en el personal ocupacionalmente expuesto, a través del análisis de la matriz de riesgo del Sistema de Evaluación de Riesgo en Radioterapia (SEVRRA). Se realizó un análisis de los laboratorios para establecer las posibilidades asociadas al riesgo (R), frecuencia (f), probabilidad de ocurrencia (P) y consecuencia(C) revisando el histórico de incidentes y resaltando debilidades y fortalezas de seguridad radiológica (SR). Posteriormente, se estableció en SEVRRA las diferentes etapas, subetapas, sucesos iniciadores, barreras de consecuencia y reductores de frecuencia. El método consistió en subdividir variables independientes de la ecuación de riesgo (R = f * P * C) en cuatro niveles cualitativos (Alto, Medio, Bajo, Muy Bajo) y con la tabulación de todas las combinaciones lógicas posibles se obtuvo cuatro niveles de riesgo (Muy Alto, Alto, Medio, Bajo), esto permitió establecer la matriz de riesgo asociada. Se obtuvo una matriz de riesgo en ambos laboratorios con resultado de riesgo bajo, así como evidentes acciones de mejora en protocolos de acceso, permanencia, logística operacional, infraestructura y equipamiento. El uso del código SEVRRA adaptado permite evaluar efectivamente la seguridad radiológica de los laboratorios y establecer una referencia para futuras evaluaciones entorno al monitoreo, mejora continua y toma de decisiones en la gestión de la protección radiológica. | es_ES |
dc.description.abstract | The Research Centre on Atomic, Nuclear and Molecular Sciences (CICANUM) owns laboratories that represent a latent radiological risk, such as, The Metrology Laboratory of Ionising Radiation (LMRI) in which there are sources of Cs137, Am241, Sr90, and an X-ray equipment with 225kV tungsten targets and 50kV molybdenum. Another laboratory is the Radiation Waste Store that contains radioactive waste from different semiperiods. For that reason, international organisms recommend performing an integral evaluation for the sake of protecting the exposed staff. Thus, the aim of this study was to evaluate CICANUM to highlight strengths and weaknesses of the implemented barriers and mitigators so the occupational risk of the occupationally exposed workers could be reduced, using an analysis of the risk matrix of the System of Evaluation of Risk in Radiotherapy (SEVRRA). An analysis of the laboratories was conducted to establish the possibilities associated with risk (R), frequency (F), probability of occurrence (P) and consequence (C), by reviewing the history of accidents and highlighting weaknesses and strengths of radiological safety (RS). Subsequently, SEVRRA establishes different stages, substages, initiating events, consequences barriers, and frequency reducers. The method consists in subdividing independent variables of the risk equation (R = f * P * C) into four qualitative levels (High, Medium, Low, Very Low) and with the tabulation of all possible logical combinations, four levels of risk were obtained (Very High, High, Medium, Low), this allowed establishing the associated risk matrix. A risk matrix was obtained from both laboratories with low-risk results, so as evident improving actions in access protocols, permanence, operational logistic, infrastructure, and equipment. The use of the adapted SEVRRA code allows to effectively evaluate the radiological safety from the laboratories and establish a reference for future evaluations regarding monitoring, continuous improvement and decision taking in the management of radiological protection. | es_ES |
dc.description.procedence | UCR::Vicerrectoría de Investigación::Unidades de Investigación::Ciencias Básicas::Centro de Investigación en Ciencias Atómicas Nucleares y Moleculares (CICANUM) | es_ES |
dc.description.procedence | UCR::Vicerrectoría de Docencia::Ciencias Básicas::Facultad de Ciencias::Escuela de Física | es_ES |
dc.identifier.citation | https://www.johamsc.com/?v=vn&numid=22 | es_ES |
dc.identifier.issn | 0719-949X | |
dc.identifier.uri | https://hdl.handle.net/10669/89658 | |
dc.language.iso | spa | es_ES |
dc.rights | acceso abierto | |
dc.source | Journal of Health and Medical Sciences, vol.4 (4), pp.243-251. | es_ES |
dc.subject | RADIACIÓN | es_ES |
dc.subject | RADIACTIVIDAD | es_ES |
dc.subject | EVALUACIÓN | es_ES |
dc.subject | SEGURIDAD | es_ES |
dc.subject | METROLOGÍA | es_ES |
dc.subject | IONIZACIÓN | es_ES |
dc.title | Evaluación de la Seguridad Radiológica del CICANUM: Laboratorio de Metrología de Radiaciones Ionizantes y Almacén de Residuos Radiactivos | es_ES |
dc.title.alternative | Radiological Safety Assessment of CICANUM: Ionizing Radiation Metrology Laboratory and Radioactive Waste Storage | es_ES |
dc.type | artículo original | es_ES |