Modelación de la transferencia de oxágeno en sistemas de aereación mediante un modelo de dos zonas simplificado
dc.creator | Durán Herrera, Esteban | |
dc.creator | Rojas Meza, Gerardo | |
dc.date.accessioned | 2015-06-19T16:10:39Z | |
dc.date.available | 2015-06-19T16:10:39Z | |
dc.date.issued | 2009-01-13 00:00:00 | |
dc.date.updated | 2015-06-19T16:10:39Z | |
dc.description.abstract | A new two zone simplified oxygen mass-transfer model with an analytical solution was proposed and used to analyze the unsteady state reaeration data of diffused reaeration systems in order to find the volumetric mass-transfer coefficients. Series of unsteady state reaeration tests in a 1000 l tank was performed to validate the model. The effect of the air flow rate and the temperature upon the mass-transfer coefficients was studied and empirical equations were used to successfully correlate them. The air flow rate was varied from 0,50 to 1,33 - 10-3 normal m3/s and the water temperature was varied from 293,25 to 303,25 K. It was found that the new model describes mathematically the aeration process very well and gives a better physical understanding of it. | |
dc.format.extent | - | |
dc.identifier.citation | http://revistas.ucr.ac.cr/index.php/cienciaytecnologia/article/view/2641 | |
dc.identifier.issn | ||
dc.identifier.uri | https://hdl.handle.net/10669/14617 | |
dc.language.rfc3066 | es | |
dc.relation.ispartof | Revista de Ciencia y Tecnología Vol. 24 Núm. 2 2009 | |
dc.title | Modelación de la transferencia de oxágeno en sistemas de aereación mediante un modelo de dos zonas simplificado | |
dc.type | artículo original |