Show simple item record

dc.contributor.advisorNavas Carro, Alejandro
dc.creatorIrías Murillo, Maciel
dc.date.accessioned2021-10-07T14:54:41Z
dc.date.available2021-10-07T14:54:41Z
dc.date.issued2021
dc.identifier.urihttps://hdl.handle.net/10669/84522
dc.description.abstractEl presente trabajo estudia el aporte de capacidad en cortante del sistema de reforzamiento de malla electrosoldada con mortero lanzado en muros de mampostería confinada una vez que han sido precargados ante cargas cíclicas en dos tipos relaciones de aspecto (h/l = 0.5 y h/l = 1). La importancia de dicha investigación radica a que este tipo de reforzamiento es actualmente muy utilizado en Costa Rica, pues se considera económico y fácil de trabajar, sin embargo, no existe teoría que respalde la utilización de dicho reforzamiento. La obtención de los resultados se dio a partir de la construcción de seis muros a escala natural, tres con una relación de aspecto h/l = 0.5 (uno patrón y dos que fueron precargados y reparados) y tres con una relación de aspecto h/l = 1 (uno patrón y dos que fueron precargados y reparados). Los resultados mostraron que una vez que los muros han sido precargados en un 94% de su capacidad máxima (paredes patrón), después de ser reparados con malla electrosoldada y mortero lanzado estos pueden volver a obtener su capacidad de carga original y sobrepasarla en 36% en el caso de los muros h/l = 0.5 y en 22% en el caso de los muros h/l = 1. Además, se pudo observar que al duplicar el valor de la relación de aspecto (de h/l = 0.5 a h/l = 1), la capacidad del aporte del reforzamiento se reduce casi a la mitad.es_ES
dc.description.abstractThe present work studies the contribution of shear capacity of the electrowelded mesh reinforcement system with mortar thrown in confined masonry walls once they have been preloaded to cyclical loads in two types of aspect ratios (h/l = 0.5 and h/l = 1). The importance of this research lies in the fact that this type of reinforcement is currently widely used in Costa Rica, since it is considered cheap and easy to work, however, there is no theory that supports the use of said reinforcement. The results were obtained from the construction of six full-scale walls, three with an aspect ratio h/l = 0.5 (one standard and two that were preloaded and repaired) and three with an aspect ratio h/l = 1 (one standard and two that were preloaded and repaired). The results showed that once the walls have been preloaded by 94% of their maximum capacity (standard walls), after being repaired with electrowelded mesh and sprayed mortar, they can regain their original load capacity and exceed it by 36%. in the case of walls h/l = 0.5 and in 22% in the case of walls h/l = 1. In addition, it was observed that by doubling the value of the aspect ratio (from h/l = 0.5 to h/l = 1), the capacity of the reinforcement contribution is reduced almost by half.es_ES
dc.description.sponsorshipIntacoes_ES
dc.description.sponsorshipPedregales_ES
dc.language.isospaes_ES
dc.sourceUniversidad de Costa Rica. San José, Costa Ricaes_ES
dc.subjectmamposteríaes_ES
dc.subjectelectrosoldadaes_ES
dc.subjectVIVIENDAS URBANAS - DISEÑO Y CONSTRUCCIONes_ES
dc.subjectCODIGO SISMICO - COSTA RICAes_ES
dc.titleEstudio experimental de la reparación de paredes de mampostería confinada reforzadas con malla electrosolodada después de ser sometidas a precarga.es_ES
dc.typetesis de maestría
dc.description.procedenceUCR::Vicerrectoría de Investigación::Sistema de Estudios de Posgrado::Ingeniería::Maestría Académica en Ingeniería Civiles_ES


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record