Buscar
Mostrando ítems 1-10 de 17
Monte Carlo dosimetry of a realistic multicellular model of follicular lymphoma in a context of radioimmunotherapy
(2020)
Purpose
Small-scale dosimetry studies generally consider an artificial environment where the tumors are spherical and the radionuclides are homogeneously biodistributed. However, tumor shapes are irregular and radiopharmaceutical ...
Modelling SPECT auto-contouring acquisitions for 177Lu & 131I molecular radiotherapy using new developments in Geant4/GATE
(2022)
Purpose
Monte Carlo modelling of SPECT imaging in Molecular Radiotherapy can improve activity quantification. Until now, SPECT modelling with GATE only considered circular orbit (CO) acquisitions. This cannot reproduce ...
Clinical implementation of PLANET® Dose for dosimetric assessment after [177Lu]Lu-DOTA-TATE: comparison with Dosimetry Toolkit® and OLINDA/EXM® V1.0
(2021)
The aim of this study was to compare a commercial dosimetry workstation (PLANET® Dose) and the dosimetry approach (GE Dosimetry Toolkit® and OLINDA/EXM® V1.0) currently used in our department for quantification of the ...
Evaluación de la calidad de imagen del PET/CT Biograph Vision 450 al variar parámetros de reconstrucción
(2023)
Los datos obtenidos por los sistemas PET/CT pasan por un algoritmo de reconstrucción antes de poder generar las imágenes. Estos algoritmos de reconstrucción permiten variar parámetros como el número de iteraciones y filtrado ...
Estudio de la dispersión en procedimientos odontológicos usando equipos de rayos X portátiles intraorales
(2023)
Los equipos de rayos X manuales son de gran utilidad en la odontología ya que son accesibles y versátiles, sin embargo, el uso manual del emisor puede ser de riesgo para los operadores y demás personal presente en el ...
Evaluation of [18F] FNM biodistribution and dosimetry based on whole-body PET imaging of rats
(2018)
Introduction: The aim of this work was to study the biodistribution, metabolism and radiation dosimetry of rats
injected with [18F]FNM using PET/CT images. This novel radiotracer targeting NMDA receptor has potential ...
Implementation of patient dosimetry in the clinical practice after targeted radiotherapy using [177Lu-[DOTATO,Tyr3]-octreotate
(2018-11-29)
Background: This study’s aim was to develop our dosimetric methodology using a commercial workstation for the
routine evaluation of the organs at risk during peptide receptor radionuclide therapy (PRRT) with 177Lu.
Methods: ...
Biological and dosimetric evaluation of [11C]S-adenosyl methionine as a potential agent for prostate cancer diagnosis
(2018)
Introduction: [11C]Choline ([11C]COL) has been widely used for prostate cancer diagnosis; however, this
radiopharmaceutical is not recommended for patients with a low absolute PSA value (< 1 ng/mL) due to its
limited ...
Pruebas técnicas de aceptación de la PET/CT del modelo Biograph Vision 450 de Siemens
(2023-11-09)
Esta tesis académica, para optar por el título de maestría académica en física médica, versa
sobre las pruebas técnicas de aceptación del sistema tomográfico PET/CT BV 450, el cual pertenece
al proyecto ciclotrón-PET/CT ...
Evaluación de la Dosis Efectiva por la Incorporación de Flúor 18 en el Personal Ocupacionalmente Expuesto del Laboratorio Ciclotrón-PET/CT
(2023)
La incorporación de radionúclidos es uno de los riesgos asociados a las prácticas de producción y manipulación de radiofármacos, por lo que, esta investigación tiene como objetivo general desarrollar una metodología para ...